Pvc Conduit Fill Table
Each row going across is a different size of pvc conduit schedule 40 or 80.

Pvc conduit fill table. Calculate your conduit fill percentage. Pvc conduit fill table this is a combination of table c10 pvc schedule 40 and table c9 pvc schedule 80 based on table 1 chapter 9 of the 2005 national electric code. Maximum number of compact conductors in rigid pvc conduit schedule 40 and hdpe conduit based on table 1 chapter 9 view full width table c11. Chapman electric offers a selection of pipe and conduit to meet your electrical or underground project needs.
The nec sets standards for the percent of volume that can safely be put into conduit. Each column going up and down is a different gauge of wire. Rigid pvc conduit schedule 80 table c9 rigid pvc conduit schedule 40 table c10 flexible metallic conduit table c3 liquidtight flexible metallic conduit table c7 liquidtight flexible nonmetallic conduit type fnmc b table c5 if you have any other questions see the nec code book or ask an ces. Information is provided as a guideline only.
Conduit wire fill charts tables. Maximum number of conductors allowed by conduit size and wire gauge. This conduit fill table is used to determine how many wires can be safely put into non pvc conduit tubing or pipe. Sch 40 and sch 80 pvc conduit.
A great tool to help electricians engineers and contractors answer the question what size conduit do i use per. This conduit fill table is used to determine how many wires can be safely put into pvc conduit tubing. Each column going up and down is a different gauge of wire. The results show the allowable number of wires for each sizetype of conduit and wire based.
Each row going across is a different size and type of conduit either emt imc or galvanized pipe rigid metal conduit rmc. Trade size interior diameter exterior diameter interior area exterior area interior volume per exterior volume per 12 062 in. Conduit fill calculator conduit fill is the percent of area inside the conduit taken up by the cables. Conduit fill chart twn75t 90 nylon.
Check your local code. The below chart is from table 1 in chapter 9 of the national electric code. Conduit wire fill charts tables. Conduit fill tables nec table c conductor size awg kcmil thhn thwn size 14 12 10 8 6 4 3 2 1 10 20 30 40 250 300 350 400 500 600 750 2 emt 241 176 111 64 46 28 24 20 15 12 10 8 7 6 5 4 4 3 2 1 rmc 200 146 92 53 38 23 20 17 12 10 8 7 6 5 4 3 3 2 1 1 imc 211 154 97 56 40 25 21 17 13 11 9 7 6 5 4 4 3 3 2 1 40 193 141 89 51 37 22 19 16 12 10 8 7 6 4 4 3 3 2 1 1 80 170 124 78.
Percent of cross section of conduit and tubing for. Home resources calculators conduit fill calculator. Maximum number of conductors or fixture wires in type a rigid pvc conduit based on table 1 chapter 9 view full width types rhh rhw and rhw 2 without outer covering.